VGZ-023 / 20120410.2 www.vogelzang.com BK100E / Page 5
CAUTION: KEEP FURNISHINGS AND OTHER
COMBUSTIBLE MATERIALS AWAY FROM THE
STOVE.
MINIMUM CLEARANCES
TO COMBUSTIBLE SURFACES
Unit to Sidewall ................................... 36 inches
Unit to Back wall ................................. 36 inches
Unit Corner to Wall .............................. 36 inches
Pipe Connector to Ceiling/Wall ........... 18 inches
LOCATING STOVE
Proper clearances must be maintained for ad-
equate air circulation. Adequate ventilation must be
provided while operating this stove.
1. The stove must be placed on solid concrete,
solid masonry, or similar non-combustible surface.
NOTE: WOODEN FLOORING COVERED WITH
TILE OR STONE MUST BE CONSIDERED A
COMBUSTIBLE SURFACE.
2. THE STOVE MUST HAVE ITS OWN FLUE. DO
NOT CONNECT THIS UNIT TO A CHIMNEY FLUE
SERVING OTHER APPLIANCES.
3. After observing the clearances to combus-
tible materials (figure 3 – 5), locate your
stove accordingly (figure 3) and careful-
ly place the stove in your selected location.
Install stove pipe, elbows, and thimble as required,
utilizing either a recently cleaned and inspected,
code-approved, 6” masonry chimney with flue
liner or a 6” i.d., maximum 64 square inch, listed
chimney.
4. Use 6” round black stove pipe. DO NOT USE GAL-
VANIZED PIPE. Secure pipe sections with three
(3) sheet metal screws in each stove pipe and/or
elbow joint to firmly hold the pipe sections together.
Screws should be spaced no more than a maximum
of 3˝/76mm apart.
DO NOT CONNECT THIS STOVE TO ANY AIR
DISTRIBUTION OR DUCT SYSTEM.
5. Recheck clearances from the stove,
connector stove pipe, and corner clearanc-
es using the illustrations (figure 3 – 5) and
your local building codes or fire protection
ordinances.
NOTE: DRYWALL FACED WITH BRICK OR STONE
MUST BE CONSIDERED A COMBUSTIBLE
SURFACE.
6. DO NOT INSTALL THIS STOVE IN A MOBILE
HOME, MANUFACTURED HOME, TENT, OR
TRAILER–NO EXCEPTIONS! (HUD Federal
Standard: 24 CFR Ch.XX)
7. The clearances provided are minimum
dimensions.
8. This stove is NOT a UL listed stove.
Fig. 3 – Floor Protector Clearances Fig. 5 – Minimum Clearances
Fig. 4 – Top View
Minimum Corner
Clearances from
Combustible Surfaces